| Item |
Description |
 |
F900-790 Dual Input Monitor
Module The F900-790 Dual Input Monitor Module is
an addressable device that provides two Style "B" (Class B) or Style "D" (Class
A) initiating device circuits to monitor dry contact initiating devices. The
module features two LED status indicators that blink during communication. Each
LED can be programmed to come on steady when the associated initiating device
circuit goes into alarm. |
 |
F900-805 Switch Monitor
Module The F900-805 Switch Monitor Module is an
addressable device that provides a Style "B" (Class B) or Style "D" (Class A)
initiating device circuit to monitor dry contact initiating devices. The Switch
Monitor Module features a LED status indicator that blinks during
communication. The LED can be programmed to come on steadily when the
initiating device circuit goes into alarm. |
 |
F900-806 Priority Switch Monitor
Module The F900-806 Priority Switch Monitor Module
is an addressable device that provides a Style "B" (Class B) or Style "D"
(Class A) initiating device circuit to monitor dry contact initiating devices.
The Priority Switch Monitor Module features a LED status indicator that blinks
during communication. The LED can be programmed to come on steadily when the
initiating device circuit goes into alarm. The Priority Switch Monitor Module
utilizes the Firecom communication interrupt protocol to provide faster
response for selected high priority devices. |
 |
F900-820 Switch Monitor I/O
Module The F900-820 Switch Monitor Input-Output
Module is an addressable device that provides a Style "B" (Class B) or Style
"D" (Class A) initiating device circuit to monitor dry contact initiating
devices and a voltage sensitive input monitoring point to monitor the absence
of DC voltage. The module's output provides a Form "C" dry contact for control
or override functions. The module features a LED status indicator that blinks
during communication. The LED can be programmed to come on steadily when the
initiating device circuit goes into alarm or the output is activated.
|
 |
F900-825 Sounder Control
Module The F900-825 Sounder Control Module is an
addressable device that provides a Style "Y" (Class B) or Style "Z" (Class A)
notification appliance circuit. The F900-825 supervises 24VDC indicating
appliances or audio circuits rated at 70.7VAC. The Sounder Control Module
features a LED status indicator that blinks during communication. |
 |
F900-830 Mini-Priority Switch
Module The F900-830 Mini-Priority Switch Monitor
Module is an addressable device that provides a Style "B" (Class B) or Style
"D" (Class A) initiating device circuit to monitor dry contact initiating
devices. The Mini-Priority Switch Monitor Module features a LED status
indicator that blinks during communication. The LED can be programmed to come
on steadily when the initiating device circuit goes into alarm. The
Mini-Priority Switch Monitor Module utilizes the Firecom communication
interrupt protocol to provide faster response for selected high priority
devices. |
 |
F900-831 Mini-Switch Monitor
Module The F900-831 Mini-Switch Monitor Module is
an addressable device that provides a Style "B" (Class B) or Style "D" (Class
A) initiating device circuit to monitor dry contact initiating devices. The
Mini-Switch Monitor Module features a LED status indicator that blinks during
communication. The LED can be programmed to come on steadily when the
initiating device circuit goes into alarm. |
 |
F900-920 Dual Input-Output
Module The F900-920 Dual Input-Output Module is an
addressable device that provides two Style "B" (Class B) or Style "D" (Class A)
initiating device circuits to monitor dry contact initiating devices. The
module's output provides two Form "C" dry contacts for control or override
functions. The module features two LED status indicator that blinks during
communication. Each LED can be programmed to come on steadily when its
associated initiating device circuit goes into alarm or the output is
activated. |
 |
F900-930 Dual Input Monitor
Module The F900-930 Dual Input Monitor Module is
an addressable device that provides two Style "B" (Class B) or Style "D" (Class
A) initiating device circuits to monitor dry contact initiating devices. The
module features two LED status indicators that blink during communication. Each
LED can be programmed to come on steady when the associated initiating device
circuit goes into alarm. |
 |
F900-940 Addressable Manual
Station The F900-940, -941, -942 and -943 are high
quality, die cast metal Addressable Fire Alarm Pull Stations. These manual
stations communicate to Firecom Model ALB-1/ALB-2 Analog Addressable Boards or
ALM-100/ALM-200 Analog Addressable Modules. The F900-940 is a single action
pull station and the F900-942 & 943 are single action pull stations with a
diagonal white stripe from left to right. The F900-941 is a dual action pull
station. A backplate with diagonal white stripe can be mounted behind the
F900-940 series manual stations if required. All models in the series have been
tested for compliance to the latest requirements of the Americans with
Disabilities Act (ADA). |
 |
F900-941 Addressable Manual
Station See F900-940 |
 |
F900-942 Addressable Manual
Station See F900-940 |
 |
F900-943 Addressable Manual
Station See F900-940 |
 |
MIO-8 Multiple Input-Output
Board The MIO-8 Multiple Input-Output Board
contains 8 addressable I/O zones. The MIO-8 communicates with the ALB-1, ALB-2,
ALM-100 or ALM-200 Analog Loop Boards/Modules. Each zone can be con figured as
one of six different styles: 1. Single Style B Input Zone 2. Single Style D
Input Zone 3. Single Style Z Output Zone 4. Dual Style Y Output Zone 5. Single
Form C Dry Contact Relay Zone 6. Firefighters/Warden Telephone Zone
|
 |
ARLY-8 Analog Relay
Card The ARLY-8 Relay Card provides 8 supervised
Style Y (Class B) relay driving circuits. External relays installed in the
field wire to the ARLY-8 card. External relays can be used to shutdown fans,
open doors or control dampers. Each circuit is rated at 24VDC @ 125mA. The
Analog Speaker Card is microprocessor controlled. The ARLY-8 receives commands
and communicates its zone status on the analog addressable loop. Zone
activation LED's are supplied for visual indication of zones activated.
|
 |
ATEL-8 Analog Telephone
Card The ATEL-8 Analog Telephone Card contains 8
Style Y (Class B) telephone circuits. Each circuit can communicate with a
firefighters phone jack or 2-wire Warden Station with confirmation LED. The
Analog Telephone Card plugs into any of the two option slots in an APB-1 Analog
Passive Backplane Motherboard. Up to two ATEL-8 Analog Telephone Cards can be
installed in a motherboard. |
 |
ASPK-8 Analog Speaker
Card The ASPK-8 Analog Speaker Card contains 8
Style Y (Class B) speaker circuits. Each circuit is rated at 15W@25VRMS or
30W@70.7VRMS. The Analog Speaker Card plugs into any of the two option slots in
the APB-1 Analog Passive Backplane Motherboard. Up to two ASPK-8 Analog Speaker
Cards can be installed in an APB-1 Analog Passive Backplane
Motherboard. |
 |
CAZ-8 Conventional Analog Zone
Card The CAZ-8 Conventional Analog Zone Card
contains 8 Style B (Class B) conventional zone circuits. Each circuit is rated
at 3mA of supervisory current. The Conventional Analog Zone Card plugs into any
of the two option slots in an APB-1 Analog Passive Backplane Motherboard. Up to
two CAZ-8 cards can be installed in an APB-1 Motherboard. |